Accident Report Detail
Accident Summary Nr: 14515746 - FINGERS CRUSHED IN POWER PRESS WHICH "DOUBLE STROKED"
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1699800 | 07/17/1984 | 2522 | 0 | Atlantic Metal Industries Inc |
Abstract: THE BRACKET SUPPORTING THE CAM RELEASE ON THE POWER PRESS WAS BROKEN, AND THE PRESS WOULD NOT OPERATE. A NEW, IMPROPERLY MADE BRACKET WAS INSTALLED ON THE PRESS. THIS BRACKET FAILED TO OPERATE CORRECTLY AND THE PRESS "DOUBLE-STROKED" WHEN THE FINGERS OF EMPLOYEE #1 WERE IN THE DIE.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1699800 | Hospitalized injury | Amputation | Occupation not reported |