Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14515670 - Employee killed by falling crane boom

Accident Summary Nr: 14515670 -- Report ID: 0420600 -- Event Date: 04/26/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
169824005/03/198416230Lee Turzillo Contracting Co

Abstract: Employee #1, a crane operator, was dismantling a crane boom by knocking out the retaining pins holding two sections together. He neglected to disconnect the pendant lines, however, which put downward pressure on the boom sections. Employee #1 was standing on the ground under the boom when he knocked out a lower pin and the boom jackknifed on top of him. He was crushed and killed.

Keywords: DISMANTLING, COLLAPSE, CRANE BOOM, WORK RULES, CONSTRUCTION, CRUSHED, STRUCK BY, FALLING OBJECT, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1698240 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.