Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14515563 - Employee killed when struck by falling headache ball

Accident Summary Nr: 14515563 -- Report ID: 0420600 -- Event Date: 04/23/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
169645904/23/198417950The Stacey Manufacturing Company
Inspection NrDate OpenedSICNAICSEstablishment Name
169643404/23/198473590Construction Equipment Intl Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
169644204/23/198449230Peoples Gas System Inc

Abstract: Employee #1 was being transported from ground level to the top of an approximately 75 ft tall natural gas holder. He was sitting atop a job-made compressed gas cylinder rack that held six oxygen and two mapp cylinders, and that was being hoisted by a Grove hydraulic crane, model # RT75S. The cylinder rack had been lifted approximately 30 ft when the manual fly section retracted without warning and the rack dropped to the ground. Employee #1 was struck by the falling headache ball and suffered a fractured skull and sternum, a compound fracture of the right femur with almost complete severing of the leg, compound fractures of the left femur and right radius, and traumatic amputation of his left ring and little fingers. He was killed. The manual fly retraction was caused by the shearing of a nonapproved safety pin.

Keywords: HYDRAULIC CRANE, FALL, STRUCK BY, EQUIPMENT FAILURE, FRACTURE, SHEAR, PIN, CONSTRUCTION, FALLING OBJECT, HEADACHE BALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1696459 Fatality Fracture Occupation not reported
2 1696434 Occupation Not Listed
3 1696442 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close