Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14514905 - EMPLOYEE KILLED BY PRESSURIZED HYDRAULIC FLUID

Accident Summary Nr: 14514905 -- Report ID: 0524700 -- Event Date: 09/26/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10627422809/22/198933630Doehler-Jarvis Incorporation

Abstract: At 7:15 a.m. on September 26, 1989, Employee #1 was killed when the pressurized hydraulic cylinder of an aluminum die casting machine broke loose releasing a stream of hydraulic fluid causing fatal cuts to Employee #1. Employee #1 was standing near the aluminum die casting machine using a data recording device when struck by the pressurized hydraulic fluid. The hydraulic cylinder had failed. A pressure relief valve was found to be defective which allowed the locking ring of the cylinder base to deform and ultimately fail.

Keywords: PPE, HYDRAULIC FLUID, COMPRESSED AIR, LACERATION, HIGH PRESSURE, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106274228 Fatality Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.