Accident Summary Nr: 14509921 - DIVER DIES WHILE HARVESTING SEA URCHINS

Accident Summary Nr: 14509921 -- Report ID: 1032300 -- Event Date: 10/29/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10701757611/23/198873890Terlouw Urchin Fisheries Company

Abstract: Employee #1, a diver, died while diving 35 feet for the commercial harvesting of sea urchins. He became separated from his umbilical cord and lift line. Upon inspection of his equipment, it was discovered that his umbilical cord was not secured to a harness. He also had released his weight belt. He surfaced in a semi-conscious state. A rescue team was not able to revive him. The dive team did not have appropriate voice communication, did not pre-plan the dive, and did not have adequate supervision.

Keywords: ASPHYXIATED, LIFELINE, SCUBA, DIVING, DROWN, COMMUNICATION, COMMERCIAL DIVING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107017576 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.