Accident Summary Nr: 14507347 - ASPHYXIATED BY NITROGEN GAS

Accident Summary Nr: 14507347 -- Report ID: 0830500 -- Event Date: 02/05/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
151522002/06/198538610Ibm Corporation

Abstract: ON FEBRUARUY 5, 1985, EMPLOYEE #1 WAS ASSIGNED TO PERFORM AN OPERATION INVOLVING REINTRODUCTION OF TONER IN A BLENDER ROOM OF THE TOWER MANUFACTURING DEPARTMENT. EMPLOYEE #1 WAS LAST SEEN ALIVE AT APPROXIMATELY 8:15 PM. AT APPROXIMATELY 8:35 PM, TWO OTHER EMPLOYEES ENTERED THE BLENDER ROOM AND FOUND EMPLOYEE #1 UNCONSCIOUS ON THE FLOOR. EMPLOYEE #1 WAS WEARING A YELLOW, FULL-BODY COVERALL WITH ATTACHED HOOD AND FACESHIELD. THE COVERALL WAS MANUFACTURED BY DURAFAB, INC., STYLE 2130Z. IT WAS THE "BESTOSHIELD SUIT," DESCRIBED AS A RESPIRATOR HOODED COVERALL. AN AIR HOSE WAS TAPED INTO THE RESPIRATOR, AND THE OTHER END WAS CONNECTED TO A NITROGEN GAS LINE WITH A QUICK-CONNECT FITTING. THE COUNTY CORONER DETERMINED THE CAUSE OF DEATH TO BE ASPHYXIATION BY THE INHALATION OF NITROGEN GAS. THE QUICK-CONNECT FITTINGS IN THE BLENDER ROOM WERE THE SAME SIZE AND TYPE FOR THE NITROGEN GAS LINES AS THEY WERE FOR THE COMPRESSED AIR GAS LINES. IN ADDITION, THE NITROGEN AND COMPRESSED AIR GAS LINES WERE OF THE SAME COLOR AND, EXCLUDING THE IDENTIFYING NAME, OF SIMILAR LABELING.

Keywords: UNCONSCIOUSNESS, AIR LINE RESPIRATOR, ASPHYXIATED, COMPRESSED AIR, INHALATION, GAS, NITROGEN, AIR LINE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1515220 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close