Accident Report Detail
Accident Summary Nr: 14506000 - ASPHYXIATED INSIDE A TEST CHAMBER
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1571801 | 04/02/1984 | 3669 | 0 | Ball Aerospace Systems Division |
Abstract: ON MARCH 31, 1984, BETWEEN 9:45 AM AND 10:15 AM, EMPLOYEE #1 ENTERED A THERMOTRON REFRIGERATION UNIT (7'X7'X7'10") WHICH WAS BEING USED AS AN ENVIRONMENTAL TEST CHAMBER. THE CHAMBER HAD BEEN FILLED WITH NITROGEN FOR COOLING PURPOSES. EMPLOYER #1 ENTERED THE CHAMBER TO INSTALL A VIDEO MONITOR, WHICH NEEDED TO BE TESTED. THE CHAMBER WAS NEITHER PURGED WITH OXYGEN PRIOR TO ENTRANCE NOR TESTED FOR OXYGEN DEFICIENCY. EMPLOYEE #1 WAS FOUND IN THE CHAMBER BY A CO-WORKER AT APPROXIMATELY 10:20 AM. THE CO-WORKER PULLED EMPLOYEE #1 FORM THE CHAMBER AND BEGAN ADMINISTERING FIRST AID. EMPLOYEE #1 WAS TRANSPORTED TO BOULDER COMMUNITY HOSPITAL BY AMBULANCE AND WAS PRONOUNCED DEAD AT 11:17 AM.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1571801 | Fatality | Asphyxia | Occupation not reported |
Translate