Accident Summary Nr: 14505465 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 14505465 -- Report ID: 0728500 -- Event Date: 09/25/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10186935209/26/198616110Loch Sand & Construction Company

Abstract: TWO EMPLOYEES WERE LOADING ABANDONED GAS AND WATER PIPES THAT HAD BEEN EXCAVATED DURING NEW ROAD CONSTRUCTION. THEY WERE IN A HURRY BECAUSE THE SALVAGE YARD TO WHICH THEY WERE SELLING THE PIPE CLOSED AT 5 PM. ONE OF THE EMPLOYEES WAS STANDING ON THE GROUND GUIDING A 20-FOOT PIPE INTO POSITION ON THE TRUCK. THE TELESCOPIC BOOM OF THE CRANE, WHICH WAS MOUNTED AT THE FRONT OF THE TRUCK, CONTACTED A 7200-VOLT OVERHEAD POWER LINE LOCATED DIRECTLY ABOVE THE BED OF THE TRUCK. THE EMPLOYEE GUIDING THE PIPE WAS ELECTROCUTED.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E C

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101869352 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.