Accident Summary Nr: 14504815 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 14504815 -- Report ID: 0728500 -- Event Date: 05/21/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
10663879405/22/199117950D.H. Griffin Wrecking Company

Abstract: An employee was clearing a 6.1-meter-long metal pipe from some fallen trees. He was going to load the pipe onto a flatbed trailer. The pipe was suspended by an 18-metric-ton hydraulic crane. Sometime during the operation, the crane operator raised the boom into contact with a 13.2-kilovolt overhead power line while the employee on the ground had his right hand on the pipe. The employee holding the pipe was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106638794 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.