Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14504179 - FOURTEEN EMPLOYEES EVACUATED AFTER CHEMICAL RELEASE

Accident Summary Nr: 14504179 -- Report ID: 0729700 -- Event Date: 07/24/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10603089307/25/198937210Learjet Corporation

Abstract: A chemical tank containing a mixture of nitric acid, hydrofluoric acid and water was emptied into a salvage tank so that the air agitator in the tank could be repaired. The salvage tank's liner had a hole in it, and the hydrofluoric acid and nitric acid mixture leaked through the liner. It ate through the steel tank and was captured in the containment pit below. The mixture began to react with the concrete, where upon the employees were evacuated and the fire department was called.

Keywords: LEAK, LUNG, HYDROFLUORIC ACID, CHEMICAL REACTION, NITRIC ACID, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106030893 Non Hospitalized injury Other Occupation not reported
2 106030893 Non Hospitalized injury Other Occupation not reported
3 106030893 Non Hospitalized injury Other Occupation not reported
4 106030893 Non Hospitalized injury Other Occupation not reported
5 106030893 Non Hospitalized injury Other Occupation not reported
6 106030893 Non Hospitalized injury Other Occupation not reported
7 106030893 Non Hospitalized injury Other Occupation not reported
8 106030893 Non Hospitalized injury Other Occupation not reported
9 106030893 Non Hospitalized injury Other Occupation not reported
10 106030893 Non Hospitalized injury Other Occupation not reported
11 106030893 Non Hospitalized injury Other Occupation not reported
12 106030893 Non Hospitalized injury Other Occupation not reported
13 106030893 Non Hospitalized injury Other Occupation not reported
14 106030893 Non Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close