Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14503627 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL PIPE

Accident Summary Nr: 14503627 -- Report ID: 0729700 -- Event Date: 08/16/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10602662808/17/198816230Insituform Missouri, Inc.

Abstract: A WORK CREW WAS REPAIRING A SEWER PIPE. THE WERE REMOVING A 4-INCH-DIAMETER FLEXIBLE METAL PIPE FROM A SEWER LINE. THEY WERE PULLING IT OUT OF A MANHOLE, THROUGH THE MANHOLE OPENING. A TUBULAR WELDED FRAME SCAFFOLD HAD BEEN ERECTED ABOVE THE OPENING, AT A HEIGHT OF 24 FEET, 3 INCHES, AND ADJACENT TO A 7200-VOLT OVERHEAD POWER LINE. ONE OF THE WORKERS WAS STANDING ON THE GROUND, PULLING UP THE SLACK IN THE PIPE AS IT WAS BEING REMOVED FROM THE MANHOLE. HE WAS ELECTROCUTED WHEN THE PIPE CONTACTED THE OVERHEAD LINE.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, MANHOLE, E GI IC, METAL PIPE, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106026628 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.