Accident Summary Nr: 14499685 - EMPLOYEES INJURED IN BUILDING COLLAPSE

Accident Summary Nr: 14499685 -- Report ID: 0523400 -- Event Date: 01/09/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10010579001/12/198717710Spancrete Industries Inc.

Abstract: AT APPROXIMATELY 1:15 PM ON JANUARY 9, 1987, EMPLOYEE #1 WAS PLACING A 48 INCH WIDE, 8 INCH THICK, 38 FOOT LONG PRECAST CONCRETE PLANK ONTO PRECAST CONCRETE BEAMS. ONE BEAM WAS 30 INCHES WIDE, 16 INCHES THICK AND 31 FEET LONG. THE OTHER BEAM WAS OF AN INVERTED "T" CONFIGURATION AND 40 INCHES WIDE, 24 INCHES THICK AND 30 1/2 FEET LONG. A 5 INCH X 8 1/8 INCH NOTCH RAN THE LENGTH OF THE BEAM AT EACH UPPER CORNER. EACH BEAM WAS SUPPORTED BY COLUMNS, 16 X 16 INCHES AND 20 FEET HIGH. THESE PLANKS WERE TO FORM THE UPPER, OR ROOF, DECK OF THE BUILDING. A MEZZANINE FLOOR, OF PRECAST PLANK RESTING ON CONCRETE BLOCK WALLS, HAD BEEN SET EARLIER IN THE DAY. THE MEZZANINE FLOOR WAS DIRECTLY BELOW THE PLANK BEING PLACED AT THE TIME OF THE ACCIDENT. EMPLOYEE #1 WAS LOCATED ON THE ROOF PLANK. EMPLOYEES #2 AND #3 WERE BENEATH THE MEZZANINE DECK, AT GROUND LEVEL, INSTALLING SEWER PIPE IN A 3 FOOT DEEP TRENCH. FIVE CONCRETE PLANKS WERE PLACED ON THE ROOF LEVEL. ALL WERE PLACED ON THE SAME SIDE OF THE INVERTED "T" BEAM. THIS CAUSED THE "T" BEAM TO ROLL TOWARD THE WEIGHTED SIDE AND OFF THE SUPPORT COLUMN. EMPLOYEE #1 WAS CRUSHED BY THE "T" BEAM AS IT FELL. EMPLOYEE #2 AND #3 WERE BURIED BY THE MEZZANINE PLANKING THAT ALSO COLLAPSED UNDER THE WEIGHT OF THE FALLING ROOF PLANK AND BEAM. EMPLOYEE #2 SUFFERED A FRACTURED LEG. EMPLOYEE #3 SUSTAINED A BACK STRAIN. BEING IN THE 3 FOOT TRENCH PROBABLY SAVED THEIR LIVES. EMPLOYEE #1 WAS KILLED AS THE "T" BEAM STRUCK HIM AS IT FELL, CRUSHING HIS BACK FROM THE SHOULDER TO PELVIC AREA.

Keywords: FRACTURE, COLLAPSE, CONSTRUCTION, BACK, CRUSHED, STRUCK BY, FALLING OBJECT, LEG, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100105790 Hospitalized injury Fracture Occupation not reported
2 100105790 Fatality Fracture Occupation not reported
3 100105790 Non Hospitalized injury Strain/Sprain Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close