Accident Summary Nr: 14499602 - EMPLOYEE IMPALED BY FLYING AIR NOZZLE COUPLER

Accident Summary Nr: 14499602 -- Report ID: 0523400 -- Event Date: 06/07/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
128128606/07/198533690Racine Die Casting

Abstract: ON JUNE 7, 1985, EMPLOYEE #1 WAS WORKING AT A VARIABLE SPEED HAMMOND POLISHING BELT LATHE, MODEL 7-ROHW-C. HE WOULD HOLD CASTINGS TO BE POLISHED AND THEN CLEAN THEM BY BLOWING COMPRESSED AIR ON THEM. AFTER CLEANING THE CASTINGS, HE WOULD DRAPE THE AIRLINE OVER THE POLISHING LATHE. THIS PRACTICE DEVELOPED BECAUSE OF THE POSITIONING OF THE AIRLINE (BEHIND THE MACHINE). THE ACCIDENT OCCURRED BECAUSE VIBRATION CAUSED THE AIRLINE TO WORK ITS WAY DOWN TO AN UNGUARDED 3 INCH LENGTH OF THE HORIZONTAL SHAFT, WHERE IT BECAME ENTWINED IN THE SHAFT. THE SHAFT, ROTATING AT 1500 RPM, QUICKLY SHEARED THE AIRLINE AND SENT THE COUPLING INTO THE EMPLOYEE'S CHEST AT A SPEED OF APPROXIMATELY 325 FEET PER SECOND. THE ACCIDENT OCCURRED BECAUSE A PORTION OF THE LATHE SHAFT WAS LEFT UNGUARDED, IN VIOLATION OF 1910.219(C)(2)(I), AND THE EMPLOYER ALLOWED THE PRACTICE TO EVOLVE OF DRAPING THE AIRLINE OVER THE LATHE. THE LATHE WAS A NEWLY MANUFACTURED UNIT, PURCHASED IN JANUARY, 1985.

Keywords: CHEST, LATHE, IMPALED, ROTATING SHAFT, STRUCK BY, FLYING OBJECT, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1281286 Fatality Puncture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close