Accident Summary Nr: 14497929 - Six employees injured by exposure to ethylene oxide

Accident Summary Nr: 14497929 -- Report ID: 0626600 -- Event Date: 08/26/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
10025101608/27/198580620Heights Hospital

Abstract: Employees #1 through #6 were working in a hospital, preparing instruments for use in surgery. Due to a mechanical failure of the pressure sensing device, an ethylene oxide sterilizer became overpressurized and caused a door seal to rupture. All six employees were exposed to ethylene oxide. They experienced eye irritation, headaches, and nausea, for which they were hospitalized.

Keywords: ETHYLENE OXIDE, HEADACHE, INHALATION, NAUSEA, RUPTURE, HIGH PRESSURE, SEAL, POISONING, OVEREXPOSURE, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100251016 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 100251016 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 100251016 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 100251016 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 100251016 Hospitalized injury Poisoning(Systemic) Occupation not reported
6 100251016 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.