Accident Summary Nr: 14497663 - Employee killed when burned by hot water from reactor

Accident Summary Nr: 14497663 -- Report ID: 0626600 -- Event Date: 04/13/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
136327404/16/198428690Union Carbide Corp

Abstract: Employee #1 and coworkers at a carbide plant were opening valves between a chilling unit and the vinyl acetate reactor's water cooling system after a chilling system was awned and installed by a contractor, Mobil Air, Inc. The chilling unit, which was also manufactured by Mobil Air, was rated at 100 PSIS. After installing the equipment, Mobil Air employees left the carbide plant. The plant employees opened valves to allow the reactor's 100 degree Celsius cooling water to circulate through the chiller. The pressure on the reactor was 138 PSIS. A cam and groove coupling manufactured by Seal Fast, Inc., and rated at 100 PSIS, failed and Employee #1 was burned by scalding water from the reactor. He was killed.

Keywords: BURN, SAFETY RELIEF VALVE, WORK RULES, EQUIPMENT FAILURE, HIGH PRESSURE, SEAL, PRESSURE RELEASE, HOT WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1363274 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close