Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14496624 - Employee killed in fall from work platform

Accident Summary Nr: 14496624 -- Report ID: 0627100 -- Event Date: 06/29/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10325410806/30/198722970Chicopee, Inc.

Abstract: Employee #1 was working on a split header from an 8 ft 3 in. high platform when the top right bolt failed and the platform fell away from the structure. He fell backward, landing on his neck and head, and was killed. Subsequent investigation showed that the mounting plates had bent, overloading the bolts and resulting in their failure. One 3/8 in. diameter by 16 in. long bolt was in place on the right side, but the left side bolt was missing and it is believed to have never been installed. The two lower 3/8 in. by 16 in. bolts were in place, one on each side. The platform, which was equipped with guardrails, had been in position since 1968 or 1969.

Keywords: COLLAPSE, INADEQUATE MAINT, WORK RULES, OVERLOADED, EQUIPMENT FAILURE, BOLT, FALL, ELEVATED WORK PLAT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103254108 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.