Accident Summary Nr: 14496301 - Employee killed in fall from suspended concrete bucket

Accident Summary Nr: 14496301 -- Report ID: 0627100 -- Event Date: 08/05/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
244479208/06/198515220Ron Latta Construction
Inspection NrDate OpenedSICNAICSEstablishment Name
244480008/06/198517910Jay Gipson Crane Co

Abstract: Employee #1 was placing reinforcing steel and pouring concrete into plasters built into a 30 ft high wall. To reach the work area, he was standing on the edge of a concrete bucket that was suspended approximately 1 to 1 1/2 ft above the wall by a 1978 P & H 22-ton capacity mobile crane. Employee #1 released his hold on the bucket and fell approximately 33 to 35 feet to the ground. He suffered a broken neck and was killed. No work platform, safety equipment, or personal protective gear were available for use on the job site.

Keywords: PPE, WORK RULES, MOBILE CRANE, CONCRETE BUCKET, ELEVATED WORK PLAT, CONSTRUCTION, FALL, FALL PROTECTION, NECK, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2444792 Occupation Not Listed
2 2444800 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.