Accident Summary Nr: 14495568 - Employee killed in 25 ft fall through roof opening
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 851501 | 04/16/1985 | 1623 | 0 | Labco Construction Inc |
Abstract: At approximately 11:45 a.m. on April 4, 1985, Employee #1 was cutting the sheetmetal top of a digester into 4-ft by 16-ft sections, with an 8-ft pie-slice-shaped bottom. The approximately 75-ft-diameter roof was 25 ft above a concrete floor and had three existing 4-ft by 8-ft openings. Employee #1 was assisting a coworker with a torch, cutting sections one at a time that were then lifted out by a crane. Employee #1 and the coworker had just prepared a section for removal and the crane operator saw Employee #1 walking parallel to the opening as the lift started. He then saw Employee #1 fall through the opening and stopped the lift. Employee #1 sustained head and internal injuries and was killed. The openings were not guarded, nor was personal fall protection equipment being used.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 851501 | Fatality | Concussion | Occupation not reported |