Accident Summary Nr: 14495154 - One employee dies, others overexposed to nitrogen atmosphere

Accident Summary Nr: 14495154 -- Report ID: 0627700 -- Event Date: 10/20/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10905913910/20/199317310Metro Electrical Contractors Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10905912110/22/199317110Anthony'S Plumbing
Inspection NrDate OpenedSICNAICSEstablishment Name
10752876210/20/199320790Bakerite Foods, Inc.

Abstract: Employees #1 and #2 were assigned to adjust the setting on a level data pressure sensor that was mounted on top of a soybean storage tank in order to regulate the low pressure nitrogen used to blanket the tank. The storage tank was 24 ft high by 30 ft diameter with a 262,000 gallon capacity. There was 1 in. of oil in the tank. Employee #2 had removed trash from the area and when he returned he could not locate Employee #1. After a short time Employee #2 climbed the tank ladder and, when he reached the top, he could see that the tank hatch was open. He looked in the tank and saw Employee #1 lying in the bottom. He yelled to Employee #3 for help, then entered the tank to assist Employee #1. Employee #3 climbed the tank and could see both Employees #1 and #2 lying in the bottom. He yelled for help, shut off the nitrogen flow to the tank, and climbed down. He was removing a side plate on the tank when coworkers arrived to assist. After removing the plate, Employee #3 held his breath and entered the tank and pulled Employee #2 to the opening. He was able to get out of the tank before being completely overcome. Employee #4 entered the tank and was able to pull Employee #1 out of the tank before being was completely overcome by the nitrogen atmosphere. Employee #1 died of asphyxia.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, WORK RULES, STORAGE TANK, OVEREXPOSURE, MAINTENANCE, CONFINED SPACE, CONSTRUCTION, NITROGEN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109059139 Fatality Asphyxia Electricians
2 109059139 Non Hospitalized injury Asphyxia Electricians' apprentices
3 109059121 Non Hospitalized injury Asphyxia Plumbers, pipefitters and steamfitters
4 107528762 Non Hospitalized injury Asphyxia Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.