Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14493522 - EMPLOYEE STRUCK BY PIECES OF EXPLODING PUMP

Accident Summary Nr: 14493522 -- Report ID: 0627400 -- Event Date: 05/08/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10740643105/12/199213810Fwa Drilling Co., Inc.

Abstract: EMPLOYEE #1, THE DERRICK MAN ON A LAND OIL DRILLING RIG, WAS OPERATING AN AUXILIARY MUD PUMP DURING THE RIGGING-UP PHASE OF DRILLING IN ORDER TO OPERATE THE CELLAR JET. THE JET BECAME CLOGGED WITH ROCKS AND DEBRIS, AND THE PRESSURE RELIEF VALVE ON THE PUMP DID NOT OPERATE. THE HIGH-PRESSURE HEADER ON THE PUMP CAME APART, AND PIECES OF IT STRUCK EMPLOYEE #1 IN THE HEAD. THE PRESSURE RELIEF VALVE WAS FOUND TO HAVE BEEN SET WITH A NAIL INSTEAD OF A MANUFACTURER'S SPECIFIED SHEAR PIN. THE NAIL AND VALVE HAD BOTH CORRODED, RENDERING THE VALVE INOPERABLE. THE HIGH-PRESSURE HEADER WAS FOUND TO HAVE SUFFERED EROSION AROUND A FITTING, WHICH FAILED UNDER PRESSURE. NO ROUTINE MAINTENANCE OR INSPECTION OF THE PUMP WAS CONDUCTED BY THE COMPANY.

Keywords: HEAD, MUD PUMP, SAFETY RELIEF VALVE, WORK RULES, OIL WELL DRILLING, STRUCK BY, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107406431 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.