Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14493324 - Employee killed in fall when derrick collapsed

Accident Summary Nr: 14493324 -- Report ID: 0627400 -- Event Date: 03/20/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10681124303/23/198913810Dramco Well Servicing, Inc.

Abstract: On March 20, 1989, Employee #1, a derrickman, was working on a well servicing rig. The telescoping Pemco derrick was set up over the well in preparation for pulling the rods out to correct a parting. He pulled the first three joinings out, and a fishing tool was then used to hook the remaining rods. As pressure was applied to pull the rods, the upper portion of the derrick collapsed. Employee #1 was thrown around in the rod basket as it fell. He was transported to a local hospital, where he died two hours later of massive internal injuries.

Keywords: DERRICK, DERRICKMAN, COLLAPSE, OIL WELL DRILLING, FALL, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106811243 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.