Abstract: Employee #1 and a coworker were in the service garage of a concrete yard mounting a multipiece rim wheel for a concrete truck. The tire was assembled and being inflated without the available safety restraining device. When the pressure reached 80 psi, Employee #1 noticed that the rim was not seated properly so he tapped the inside of it with a sledge hammer. The wheel assembly exploded, striking Employee #1 in the forehead. He sustained massive head injuries and died the following day. An investigation revealed that the restraining device was not used, an in-line air valve with pressure gauge or regulator was not provided, Employee #1 struck a pressurized wheel assembly, and the employees were using incompatible rim components.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 759407 | Fatality | Concussion | Occupation not reported |