Accident Summary Nr: 14491245 - FLAMMABLE VAPORS IGNITED BY SPARK, EMPLOYEES BURNED

Accident Summary Nr: 14491245 -- Report ID: 0214500 -- Event Date: 05/30/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
227295305/30/198530890Glow Plastics Corp.

Abstract: EMPLOYEES #1 AND #21 WERE ASSIGNED THE JOB OF TENDING A 100 GALLON (WATER JACKET) REACTOR KETTLE OF METHYL METHACRYLATE IN THE MIXING ROOM. EMPLOYEE #1 WAS STANDING BETWEEN KETTLE #1 AND KETTLE #2, PREPARING TO CHECK THE VISCOSITY OF THE LIQUID PRODUCT. EMPLOYEE #2 WAS STANDING 5 FEET SOUTH OF EMPLOYEE #1, ASKING HIM HOW THE BATCH WAS PROGRESSING. EMPLOYEE #1 USED A METAL WRENCH (VISEGRIPS) TO PRY OPEN THE COVER OF KETTLE #1. THE WRENCH HANDLE STRUCK THE ANGLE IRON SUPPORT FOR THE AGITATOR MOTOR, PRODUCING A SPARK. EMPLOYEE #2 NOTICED THE SPARK, WHICH WAS IMMEDIATELY FOLLOWED BY A MASSIVE "FIRE BALL". EMPLOYEE #1 AND #2 WERE ENGULFED IN THE FIREBALL. EMPLOYEE #3 CAME TO THE AREA OF KETTLE #1 TO ASSIST THE OTHER EMPLOYEES AND ALSO RECEIVED INJURIES. ALL THREE EMPLOYEES RECIEVED FIRST AND SECOND DEGREE BURNS ON THEIR FACE, ARMS AND ABDOMEN. EMPLOYEE #2 ALSO RECEIVED SOME THIRD DEGREE BURNS. NO BONDING OR GROUNDING WAS USED FOR THE TRANSFER OF FLAMMABLE LIQUIDS; NOR WERE NON-SPARKING TOOLS PROVIDED.

Keywords: BURN, ABDOMEN, FLAMMABLE VAPORS, SPARK, ARM, FACE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2272953 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 2272953 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 2272953 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close