Accident Report Detail
Accident Summary Nr: 14490759 - Employee killed in tank truck explosion
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 18149633 | 10/04/1988 | 7699 | 0 | Domermuth Petroleum Equip. & Maint. Corp. Dba |
Abstract: Employee #1 was attempting to clean sludge from a tank truck that had contained flammable materials, such as gasoline or oil. Employee #1 was sitting on top of the truck with his feet dangling inside one of the hatch openings. He had a trouble light in the vicinity of the hatch opening and the nozzle end of a water pressure washer unit to clean the inside of the tank. When Employee #1 pulled the trigger of the nozzle, an explosion occurred that blew him through the roof of the building. Employee #1 was killed. Apparently, the tanker had not been ventilated to remove the flammable vapors, which, in combination with the water from the nozzle hitting the hot bulb of a non-explosion-proof trouble light, caused the explosion.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18149633 | Fatality | Other | Occupation not reported |