Accident Summary Nr: 14489942 - Employee killed when excavation shoring collapses

Accident Summary Nr: 14489942 -- Report ID: 0215800 -- Event Date: 08/20/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
225661808/21/198516290Case Boring Corp.
Inspection NrDate OpenedSICNAICSEstablishment Name
225660008/21/198516230William J. Keller & Sons Construction Co., Inc.

Abstract: At approximately 2:00 p.m. on August 20, 1985, Employee #1 and three coworkers were boring a hole to push a 20 in. casing underneath a road. Employee #1 was in the approximately 9 ft wide by 32 ft long by 7 ft deep excavation. Two 8 ft by 15 ft by 3/4 in. steel plates without horizontal braces had been placed against the north and south walls of the excavation at an angle of approximately 30 degrees. The plate on the south wall tipped over and pinned Employee #1 against the casing, crushing his chest. He suffered cardiac arrest as a result of internal injuries, and was pronounced dead approximately 45 minutes later.

Keywords: STEEL PLATE, EXCAVATION, WORK RULES, BRACING, COLLAPSE, PINNED, CONSTRUCTION, CARDIAC ARREST, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2256618 Fatality Fracture Occupation not reported
2 2256600 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close