Accident Summary Nr: 14489843 - VEHICLE FELL FROM HOIST

Accident Summary Nr: 14489843 -- Report ID: 0215800 -- Event Date: 11/01/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
201603811/02/198475380Appleton Garage Inc

Abstract: THE EMPLOYEE WAS ATTEMPTING TO REMOVE A BATTERY CABLE. HE WAS STANDING UNDER THE FRONT END OF THE PICK UP TRUCK, WHICH WAS POSITIONED ON A HYDRAULIC HOIST APPROXIMATELY 6' ABOVE THE FLOOR. THE HOIST WAS OF THE H FRAME TYPE WITH EXTENDABLE ARMS THAT COULD BE POSITIONED TO FIT THE FRAME OF ANY VEHICLE. AT THE END OF EACH ARM WAS A PAD APPROXIMATELY 8" LONG WHICH IS NORMALLY FLIPPED UP TO CATCH THE FRAME, AND ALLOWS THE HOIST TO CLEAR ANY OBSTRUCTIONS ON THE BOTTOM OF THE VEHICLE, SUCH AS THE MUFFLER OR TAIL PIPE. THE TRUCK TIPPED FORWARD AND FELL FROM THE HOIST. EMPLOYEE #1 WAS PINNED BETWEEN THE SNOWPLOW FRAME (MOUNTED AT THE VEHICLE FRONT END) AND THE FLOOR. EMPLOYEE #1 SUFFERED FROM PULMONARY ARREST AND COLLAPSED LUNGS. IT WAS APPARENT THAT THE TRUCK WAS NOT PROPERLY POSITIONED ON THE HOIST. THE EXTRA WEIGHT OF THE PLOW FRAME AND THE DIFFERENTIAL (4 WHEEL DRIVE) WERE NOT CONSIDERED.

Keywords: HEART, HYDRAULIC LIFT, LUNG, CRUSHED, TRUCK, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2016038 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close