Accident Report Detail
Accident Summary Nr: 144861.015 - Employee is killed when struck by fallen piece of metal
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1584599.015 | 03/21/2022 | 1541 | 236210 | 75341 - Hall Construction Llc |
Abstract: At 9:30 a.m. on March 19, 2022, employees were removing old cyclones to replace them with new cyclones. Employees were cutting the old cyclones into smaller pieces and pushing them off of a platform approximately 40 feet 10 inches above the floor. Employee #1 was working as the spotter and was struck by a fallen piece of metal and died due to generalized blunt force trauma. Employee #1 was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1584599.015 | 55 | M | Fatality | Occupation not reported |
Translate