Accident: 14484158 - Crushed By Machine

Accident: 14484158 -- Report ID: 0213100 -- Event Date: 10/24/1985
InspectionOpen DateSICEstablishment Name
1781031810/24/19852515Sealy Of Eastern New York Inc.

EMPLOYEE #1 WENT UNDERNEATH THE GARNETT MACHINE TO MAKE REPAIRS ON A CHAIN AND SPROCKET. HE WAS PULLED INTO THE GARNETT MACHINE AND WAS CRUSHED BY ROTATING CYLINDERS. HE DIED IMMEDIATELY.

Keywords: garnett machine, repair, cylinder, crushed

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 17810318 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.