Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14480693 - EMPLOYEE'S HAND PULLED INTO NIP POINT OF PAPER ROLLERS

Accident Summary Nr: 14480693 -- Report ID: 0214200 -- Event Date: 05/13/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10087325605/14/198727520L.P. Thebault Co.

Abstract: AT 2:20 PM ON MAY 13, 1987, EMPLOYEE #1, A "HAND WORKER" FOR A COMMERCIAL PRINTING COMPANY, REACHED INTO THE EXITING CARRIER ROLLERS OF A MODEL B-22 "STAHL" #4 BUCKLE FOLDER MACHINE WITH HER LEFT HAND. SHE WAS TRYING TO REMOVE WASTE PAPER JAMMED BETWEEN THE EXPOSED NIP POINTS OF THE ROLLERS. HER FINGERS TOUCHED THE UNGUARDED IN-RUNNING ROLLERS AND WERE PULLED INTO THE NIP POINT LOCATED 36 INCHES ABOVE THE WORK FLOOR. THE COMPANY HAD NO SYSTEM IN PLACE TO PREVENT EMPLOYEE CONTACT WITH THESE IN-RUNNING ROLLERS.

Keywords: FINGER, WORK RULES, CAUGHT BY, ROLLER CONVEYOR, JAMMED, LOCKOUT, ROLLER--MACH/PART, NIP POINT, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100873256 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close