Accident Summary Nr: 14473409 - EMPLOYEE DIED DUE TO ASPHYXIA AND FIVE OTHERS INJURED

Accident Summary Nr: 14473409 -- Report ID: 0521400 -- Event Date: 07/27/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10320254507/28/198935230A.O. Smith Engineered Storage Products Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10320250307/28/198917960Central Machinery Movers

Abstract: Two employees entered a 12-ft by 20-ft by 12-ft-deep pit. Carbon monoxide from the nearby heating operation was pulled into the space. Employee #2 became nauseous and left the pit while Employee #1 stayed. Other employees found Employee #2 staggering in the hallway and saw Employee #1 lying unconscious in the pit. Employees #3, 4, 5, and 6 entered the pit to rescue Employee #1. Employees #3, 4, 5, and 6 all became disoriented and attempted to immediately leave the pit. Employee #3 had to be pulled from the pit by Employees # 4, 5, and 6. The local fire department arrived and pulled Employee #1 from the pit. All six employees were transported to the hospital. Employee #1 died of asphyxia. Employees #2 and 3 were hospitalized for asphyxia. Employees #4, 5, and 6 were treated for asphyxia and released.

Keywords: ASPHYXIATED, CARBON MONOXIDE, CONFINED SPACE, GAS, NAUSEA, PIT, CHEMICAL VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103202545 Fatality Asphyxia Occupation not reported
2 103202545 Hospitalized injury Asphyxia Occupation not reported
3 103202545 Hospitalized injury Asphyxia Occupation not reported
4 103202545 Non Hospitalized injury Asphyxia Occupation not reported
5 103202545 Non Hospitalized injury Asphyxia Occupation not reported
6 103202545 Non Hospitalized injury Asphyxia Occupation not reported
7 103202503 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.