Accident Summary Nr: 14467849 - EMPLOYEE ASPHYXIATED IN GASOLINE TANK

Accident Summary Nr: 14467849 -- Report ID: 0155010 -- Event Date: 01/30/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1520346601/30/198517990Jacksons Waste Oil Service

Abstract: EMPLOYEE #1 DESCENDED THROUGH A 16 INCH DIAMETER ACCESS OPENING INTO AN UNVENTILATED ABOVE-GROUND (10 1/2 FEET DEEP, 33 FEET LONG) 20,000 GALLON LEADED GASOLINE STORAGE TANK. HE WAS WEARING A REXNORD (BIOMARINE) BIO PAK 45 CLOSED CIRCUIT BREATHING APPARATUS. HIS JOB WAS TO CLEAN SLUDGE FROM THE BOTTOM OF THE TANK (SUB-CONTRACT JOB). WITHIN ONE MINUTE OF ENTRY, THE EMPLOYEE WAS SEEN TO COLLAPSE, FACE DOWN, INTO 1 1/2 INCH OF SLUDGE AND LEADED GASOLINE. THE EMPLOYEE WAS NOT EQUIPPED WITH A SAFETY BELT (OR HARNESS) OR A LIFELINE. A CO-WORKER IMMEDIATELY CLIMBED INTO THE TANK (WITHOUT ANY RESPIRATORY PROTECTION) AND ATTEMPTED TO TIE A ROPE AROUND THE 6 FOOT, 185 POUND INDIVIDUAL. HE WAS UNSUCCESSFUL, AND NEARLY OVERCOME BY FUMES AND/OR OXYGEN DEFICIENCY HIMSELF DURING HIS SECOND DESCENT. RESPONDING FIRE FIGHTERS FOUND NO PULSE ON EMPLOYEE #1. THEY REMOVED HIM FROM THE TANK AND ADMINISTERED 100% OXYGEN AND CPR. HOWEVER, THE EMPLOYEE WAS PRONOUNCED DEAD ON ARRIVAL AT A LOCAL HOSPITAL.THE OUTSIDE TEMPERATURE WAS 14 DEGREES F. A PRELIMINARY AUTOPSY INDICATED DEATH WAS DUE TO AN OXYGEN DEFICIENCY. THE TANK PROBABLY HAD A HYDROCARBON ENRICHED ATMOSPHERE, DISPLACING THE OXYGEN CONTENT.

Keywords: OXYGEN DEFICIENCY, RESPIRATORY, CONFINED SPACE, WORK RULES, AIR MONITORING, TANK CLEANING, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15203466 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close