Accident Summary Nr: 14467286 - Employee killed when crane rigging fails and load falls

Accident Summary Nr: 14467286 -- Report ID: 0626000 -- Event Date: 01/26/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
84087601/29/198516290Ebasco Constructors Inc

Abstract: At approximately 9:40 a.m. on January 26, 1985, Employee #1 and coworkers were preparing to lift a 10 1/2 ft by 12 ft steel platform from the ground to a shaft on the 95 ft high roof level of a building under construction. The rigger hooked up the approximately 3500 lb platform, and the crane lifted it to a point approximately 25 ft above the shaft. Employee #1, a flagman, was hooking up sound-activated headphones when the eyebolts pulled out of the load and it fell, striking and killing him. The platform had been built on site and originally had 1 1/8 in. eyebolts on the four corners, with the corresponding nuts welded to the underside. The original eyebolts had disappeared sometime before the accident, and had been replaced with two 1 in. eyebolts when the platform was moved about 10 days before the accident. These new eyebolts held at that time, but during this move they pulled out of the 1 1/8 in. nuts, and the platform fell.

Keywords: PLATFORM, RIGGING, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, BOLT, STRUCK BY, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 840876 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close