Accident Summary Nr: 14461396 - Three employees injured by falling crane boom

Accident Summary Nr: 14461396 -- Report ID: 0257210 -- Event Date: 07/13/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1511979507/19/198417310North Caribbean Electrical Corporation
Inspection NrDate OpenedSICNAICSEstablishment Name
1511727807/16/198415210Rido Construction Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
1511980307/19/198416110Desuja Construction Corporation
Inspection NrDate OpenedSICNAICSEstablishment Name
1511969607/19/198417110Rafael Albino Ramos

Abstract: Employee #3 was hoisting a crawler crane boom with an attached concrete bucket when suddenly the supporting cable broke and the boom fell. It struck Employee #1, severely injuring his right arm and leg. When the boom fell into the wood forms of the roof, Employee #2 was thrown to the ground and sustained minor body lacerations. Employee #3, the crane operator, suffered minor lacerations on his face and body.

Keywords: CRANE BOOM, CRAWLER CRANE, BROKEN CABLE, STRUCK BY, EQUIPMENT FAILURE, BOOM SUPPORT CABLE, FRACTURE, CONSTRUCTION, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15119795 Hospitalized injury Fracture Helpers, construction trades
2 15119795 Non Hospitalized injury Bruise/Contus/Abras Helpers, construction trades
3 15119795 Non Hospitalized injury Bruise/Contus/Abras Crane and tower operators
4 15117278 Occupation Not Listed
5 15119803 Occupation Not Listed
6 15119696 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.