Accident Summary Nr: 14459366 - MACHINIST INJURED WHEN PULLED INTO OPERATING LATHE

Accident Summary Nr: 14459366 -- Report ID: 0352420 -- Event Date: 10/21/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
10202209210/28/198540130Bethlehem Steel Plant

Abstract: ON OCTOBER 21, 1985, AT 8:55 AM, EMPLOYEE #1, WHO WAS WEARING A LOOSE SWEATER BECAUSE OF CHILLY WEATHER, WAS USING A 14 INCH FLAT FILE TO REMOVE BURRS FROM AN EIGHT INCH DIAMETER, SEVEN INCH WIDE, FIVE GROOVE SHEAVE. THE SHEAVE WAS ROTATING AT 54 RPM IN A REED-PRENTICE 20 INCH SLIDING GEAR HEAD LATHE (SER. #44928). THE SHEAVE WAS 43 INCHES ABOVE THE FLOOR AND 12 INCHES FROM THE STANDING SPACE. A FOUR INCH "C" CLAMP SECURED THE DOG WHICH HELD THE SHEAVE. THE "C" CLAMP HANDLE WAS TAPED TO THE DOG TO PREVENT MOVEMENT OF THE HANDLE. THE HANDLE PROJECTED 3/8 INCH BEYOND THE CHUCK. AS THE SHEAVE ROTATED, THE "C" CLAMP HANDLE CAUGHT IN THE POCKET OF EMPLOYEE #1'S SWEATER AND PULLED HIM INTO THE LATHE. THE FOREMAN GRABBED EMPLOYEE #1 AROUND THE WAIST AND PULLED HIM AWAY FROM THE LATHE. EMPLOYEE #1 RECEIVED A BROKEN SHOULDER BLADE, THREE CRACKED RIBS AND A GASH IN THE CHIN. THE LATHE STOP BUTTON WAS LOCATED IN THE STANDING SPACE, 17 1/2 INCHES ABOVE THE FLOOR. THE RIGHT HAND STOP LEVER WAS 29 INCHES AWAY, 20 1/2 INCHES FROM THE FLOOR. THE LEFT HAND STOP LEVER WAS 36 INCHES AWAY, 24 INCHES FROM THE FLOOR.

Keywords: FRACTURE, LATHE, MAINTENANCE, SHOULDER, MACHINIST, LACERATION, RIB, ENTANGLED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102022092 Hospitalized injury Fracture Machinists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.