Accident Summary Nr: 14457204 - CRUSHED BY UNSECURED ROCKET MOTOR

Accident Summary Nr: 14457204 -- Report ID: 0854910 -- Event Date: 12/10/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
328059112/10/198437240Hercules Inc Aerospace Division

Abstract: EMPLOYEE #1 WAS MOUNTING A ROCKET MOTOR ONTO A STATIC TEST STAND. THE MOTOR WAS TRANSFERRED INTO THE TEST BAY ON A CRADLE. IT WAS REMOVED FROM THE CRADLE BY TWO ELECTRICALLY OPERATED HYDRAULIC JACKS. THE JACKS WERE CONNECTED, VIA BALL AND PIN CONNECTORS, TO THE ROCKET MOTOR ABOUT 18 INCHES ABOVE FLOOR LEVEL. THE MOTOR WAS THEN BOLTED TO FOUR (4) YOKES AND SHEAR STANDS. THE MOTOR WAS UNHOOKED FROM THE HOIST JACKS BEFORE THE END BLOCKS HAD BEEN INSTALLED. EMPLOYEE #1 WAS UNDERNEATH THE MOTOR, REMOVING THE TEMPORARY TRACKS. THE MOTOR SHIFTED LONGITUDINALLY, TEARING LOOSE FROM TWO STANDS AND BADLY BENDING THE OTHER TWO. THE ROCKET MOTOR THEN DROPPED ONTO EMPLOYEE #1, CRUSHING HIM AGAINST THE SECURING BEAMS.

Keywords: ROCKET MOTOR, UNSECURED, BLOCKS, CRUSHED, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3280591 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close