Accident Summary Nr: 14456966 - STRUCK BY FALLING CRANE BLOCK

Accident Summary Nr: 14456966 -- Report ID: 0854910 -- Event Date: 07/27/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1518999608/02/198449110Utah Power & Light

Abstract: AN EMPLOYEE HAD POSITIONED A HYDRAULIC TELESCOPING CRANE, MOUNTED ON AN M8 TANK RETRIEVER, FOR DISMANNTLING A TWO-POLE STRUCTURE. INFORMED THAT A NEW POSITION MUST BE TAKEN FOR HEIGHT, THE EMPLOYEE STARTED RETRACTING THE BOOM AND TAKING LOAD LINE UP AT THE SAME TIME. THE BOOM HAD BEEN EQUIPPED WITH A 20-FOOT-LONG JIB TO INCREASE HEIGHT CAPABILITY, BUT THE JIB HAD NOT BEEN EQUIPPED WITH ANY TYPE OF DEVICE TO WARN THE OPERATOR OF IMPENDNG TWO-BLOCKING. AS THE LOAD LINE WAS BEING TAKEN UP, THE ATTACHED BLOCK WAS PULLED UP AND OVER THE END SHEAVE. IT THEN SLID DOWN THE BOOM, FALLING INTO THE CAB. THE BLOCK STRUCK THE EMPLOYEE'S HAND, BREAKING IT.

Keywords: ELEC UTILITY WORK, STRUCK BY, TWO-BLOCKING, CRANE BLOCK, FALLING OBJECT, CRANE, HYDRAULIC CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15189996 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close