Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14454763 - Employee crushed and killed when bulldozer overturns

Accident Summary Nr: 14454763 -- Report ID: 0728100 -- Event Date: 08/20/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10191807608/26/198617940Rock Valley Cement Block & Tile Company

Abstract: Employee #1 was backing a D-6 bulldozer onto a lowboy trailer during a light rain. The bulldozer was too close to the edge of the trailer and it slid off, rolling over on its side. Employee #1 was crushed and killed by the cab of the bulldozer. His body was removed by digging out the dirt from under the cab. Employee #1 was not wearing a seat belt, which might have saved his life.

Keywords: WORK RULES, EQUIPMENT OPERATOR, CONSTRUCTION, EARTHMOVING EQUIP, CRUSHED, SEAT BELT, BULLDOZER, BACKING UP, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101918076 Fatality Other Grader, dozer and scraper operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close