Accident Summary Nr: 14449748 - EMPLOYEE DIED FROM INHALATION OF VAPORS FROM ADHESIVE

Accident Summary Nr: 14449748 -- Report ID: 0552700 -- Event Date: 11/11/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10454797111/12/198755510Detroit Marine, Inc.

Abstract: EMPLOYEE #1 WAS ASSIGNED TO REPLACE CARPETING ON THE FLOOR OF A 17 FOOT FIBERGLASS BOAT. THE BOAT WAS LOCATED IN A REPAIR GARAGE HAVING A FLOOR AREA OF 28 BY 30 FEET AND A 10 FOOT CEILING. NO VENTILATION WAS PROVIDED EXCEPT FOR A COMMON HOUSEHOLD FAN USED TO BLOW HEATED AIR FROM AN ADJACENT ROOM 25 FEET AWAY. THE EXTERIOR GARAGE DOORS WERE CLOSED. EMPLOYEE #1 BEGAN REMOVAL OF THE OLD CARPETING AT ABOUT 10:45 AND THEN BEGAN APPLICATION OF LESS THAN 1 QUART OF "WELDWOOD CONTACT CEMENT - NON-FLAMMABLE FORMULA". HE WORKED ALONE IN THE ROOM. AT 11:45 HE LEFT THE AREA BECAUSE HE HAD USED UP THE ADHESIVE. HE WENT TO A LOCAL STORE AND PURCHASED A 1 PINT CAN OF "WELDWOOD CONTACT CEMENT - ORIGINAL FORMULA" AND RETURNED TO THE GLUING TASK AT APPROXIMATELY 12:15. AT 12:45 ANOTHER EMPLOYEE ENTERED THE AREA LOOKING FOR EMPLOYEE #1. HE DID NOT SEE EMPLOYEE #1, SO HE WENT OUTSIDE TO LOOK FOR HIM. AT APPROXIMATELY 1 PM, ANOTHER EMPLOYEE ARRIVED ON SITE AND JOINED IN THE SEARCH. SHORTLY THEREAFTER, EMPLOYEE #1 WAS LOCATED LYING FACE DOWN IN THE BOAT. HE WAS REMOVED FROM THE BOAT AND CPR WAS ADMINISTERED UNTIL AMBULANCE ATTENDENTS ARRIVED. THEY TOOK OVER CPR AND TRANSPORTED EMPLOYEE #1 TO THE HOSPITAL. THE AUTOPSY REPORT REVEALED ACUTE, HEMORGHAGIC TRACHEOBRONCHITIS, CONGESTION OF THE KIDNEYS, EDEMA OF THE BRAIN AND GALL BLADDER, AN ATROPHIC THYMUS, ENLARGED LYMPH NODES AND MILD DILATION OF ALL HEART CHAMBERS.

Keywords: RESPIRATORY, VAPOR, VENTILATION, WORK RULES, INHALATION, CHEMICAL VAPOR, KIDNEY, BRAIN, BOAT, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104547971 Fatality Poisoning(Systemic) Not specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close