Accident Summary Nr: 144491.015 - Employee amputates three fingers while using press punch mac

Accident Summary Nr: 144491.015 -- Report ID: 0524700 -- Event Date: 02/21/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1581905.01502/22/2022332119Fulton Industries Inc.

Abstract: On February 21, 2022, three flashlight production line employees were tasked with performing flashlight assembly work. The three employees arrived on site in the Flashlight Assembly Room at approximately 8:00 a.m., where they were tasked with duties that included, but not limited to, flashlight line assembly, back stripping flashlights, and operating a mechanical punch press machine. Employee #1 was operating Machine #252 (Havir Manufacturing Co., Press-Rite Single Trip Clutch Model #1-1/2 full revolution punch press machine) with pierce flashlight reflector trim die (#1004-1 pierce flashlight). Employee #1 was tasked with operating machine #252 to pierce two to four boxes of raw product, i.e., metal reflector pieces that were approximately 6.3 inches in circumference with approximately 1,5000 pieces per box. Machine #252 procedures required the operator to be in a seated position directly in front of the machine. Employee #1 manually fed the raw product from the right side into the die, the point of operation, then pressed the foot pedal which tripped a full revolution clutch. After the foot pedal is pressed, the machine would complete a cycle that resulted in two hole punches into the reflector piece, and the operator would manually remove the final product from the left side, and place the piece into a finished product box. At 11:15 a.m., during operation of machine #252, Employee#1 was manually handling a product piece with her left hand and activated the full revolution clutch by pressing her foot onto the foot pedal, which resulted in her first and second fingers of her left hand to be caught in the point of operation between the die block and the punch plate of the die set. Employee #1 suffered amputation injuries of her first and second fingers of her left hand. Employee #1 was hospitalized.

Keywords: Amputated, Amputation, Caught In, Die, Finger, Foot pedal, Machine Cycled, Pinched, Point Of Operation, Punch Press

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1581905.015 47 F Hospitalized injury Assemblers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close