Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14447957 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU CRANE BOOM

Accident Summary Nr: 14447957 -- Report ID: 0552700 -- Event Date: 04/11/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1488790504/12/198415210Chandler-Wilbert Vault Co

Abstract: TWO EMPLOYEES WERE ASSIGNED THE DUTIES OF DELIVERY AND INSTALLATION OF PREFABRICATED STEPS AT THE REAR ENTRY OF A RESIDENCE. THREE DIFFERENT SETS OF OVERHEAD POWER LINES WERE IN THE AREA WHERE THE STEPS WERE TO BE PLACED. THE TRUCK CRANE COULD NOT REACH THE POSITION WHERE THE STEPS WERE TO BE PLACED. THE OPERATOR LET THE STEPS DOWN, AND THE HELPER UNHOOKED THE CABLE FROM THE STEPS. WHEN THE OPERATOR, USING HAND CONTROLS AND STANDING ON THE GROUND, WENT TO SWING THE BOOM AROUND TO PICK UP THE STEPS AT ANOTHER ANGLE, THE CABLE CAME IN CONTACT WITH AN 8000-VOLT OVERHEAD POWER LINE. THE OPERATOR WAS KNOCKED UNCONCIOUS, AND MOUTH-TO-MOUTH RESUSITATION WAS USED TO REVIVE HIM. HE RECEIVED BURNS ON THE FINGERS OF HIS RIGHT HAND AND ON HIS LEFT FOOT. HUMIDITY WAS HIGH (62%), AND THE GROUND MOIST FROM OVERNIGHT DRIZZLE. THE OPERATOR HAD ATTEMPTED TO POSITION THE BOOM IN BETWEEN THE SETS OF POWER LINES, WHICH WERE ONLY 9 FEET APART.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CPR, CRANE BOOM, E C, ELECTRIC SHOCK, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14887905 Hospitalized injury Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.