Accident Summary Nr: 14445480 - EMPLOYEE KILLED IN TRENCH CAVE-IN

Accident Summary Nr: 14445480 -- Report ID: 0552700 -- Event Date: 08/16/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10458890008/18/198617940Kenneth Goon Contractor

Abstract: EMPLOYEE #1 WAS WORKING AS A LABORER, HELPING TO INSTALL DRAINAGE PIPE ACROSS A DIRT ROAD FROM FIELD TO FIELD. A 66 FOOT LONG TRENCH HAD JUST BEEN DUG ACROSS THE ROAD, FROM A SOUTHERLY TO NORTHERLY DIRECTION, USING A BACKHOE. TWO 30 FOOT SECTIONS OF PIPE, COUPLED TOGETHER, WERE TO BE SET INTO THE TRENCH, SLOPING SLIGHTLY TO THE NORTH. THE TRENCH HAD BEEN DUG SO THAT THE WALLS WERE STRAIGHT UP AND DOWN. THERE WAS NO MEANS OF SUPPORT, NOR WAS THERE AN EXIT. EMPLOYEE #1 WAS STANDING AT THE CENTER LINE OF THE ROAD IN THE MIDDLE OF THE TRENCH. THE TRENCH DEPTH THERE WAS SIX FEET AND THE WIDTH 2 1/2 FEET. THE SOIL WAS SATURATED AND CONSISTED OF SILTY CLAY AND BLACK DIRT. EMPLOYEE #1 WAS REMOVING CHUNKS OF SILTY CLAY MATERIAL, BY HAND, WHICH HAD BROKEN AWAY FROM THE BOTTOM FOOT AND A HALF OF THE TRENCH WALL. EMPLOYEE #1 WAS REMOVING THIS MATERIAL SO THAT THE PROPER SLOPE COULD BE OBTAINED FOR THE DRAINAGE PIPE TO BE PLACED. THE TRENCH WALLS BECAME UNDERCUT AND UNSTABLE WHERE THE SILTY MATERIAL FELL OFF. A FRACTURE OCCURRED, CAUSING A PIECE OF MATERIAL, APPROXIMATELY 10 FEET LONG, 2 1/2 FEET WIDE AND 4 1/2 FEET DEEP TO BREAK AWAY FROM THE EAST WALL. THE LARGE PIECE STRUCK EMPLOYEE #1 AND PINNED HIM TO THE WEST WALL. THE MATERIAL COVERED THE EMPLOYEE UP TO ABOUT HIS SHOULDERS. EMPLOYEE #1 DIED FROM ASPHYXIATION BY CRUSHING. HE SUSTAINED A BROKEN CLAVICLE, RIBS, AND OTHER INJURIES ASSOCIATED WITH CRUSHING.

Keywords: ASPHYXIATED, WORK RULES, CONSTRUCTION, TRENCH, CRUSHED, SHORING, SLOPING, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104588900 Fatality Other Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close