Accident Summary Nr: 14444400 - EMPLOYEE'S FINGER FRACTURED BY CUTTING MACHINE

Accident Summary Nr: 14444400 -- Report ID: 0355119 -- Event Date: 06/21/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10569806206/22/198926550Yarn Carriers, Inc.

Abstract: About 3:30 p.m. on June 21, 1989, Employee #1 fractured his left middle finger while operating a paper tube recutter machine. The paper tubes are cut as follows. A paper tube, 39.5-in. long by 2.5-in. in diameter is placed onto an open-end mandrel shaft. The employee pulls a mechanical handle, placing five cutting blades against the paper tube. The handle activates an electrical switch that signals a two-way reversing valve solenoid to operate a two-way air cylinder at 80 psi. While in the cutting mode, a rod is connected to a stabilizing arm and roller that moves down, putting pressure on the open end of the tube mandrel shaft. In this case, the air switching solenoid was hooked up in reverse, so that when the power was off, the stabilizer came down under pressure. As Employee #1 was sliding a paper tube onto the mandrel shaft, lightning struck, momentarily killing the plant power, and the shaft stabilizer came down on Employee #1's left middle finger, fracturing it.

Keywords: FRACTURE, SLICER, FINGER, LIGHTNING, MANDREL, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105698062 Non Hospitalized injury Fracture Slicing and cutting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close