Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14443824 - Struck By Crane Boom On Lattice Boom Truck

Accident: 14443824 -- Report ID: 0355114 -- Event Date: 12/12/1984
InspectionOpen DateSICEstablishment Name
331920912/13/19841611Corman Construction Inc

EMPLOYEE #1 WAS APPARENTLY DISASSEMBLING THE BOOM OF A 65' LATTICE BOOM TRUCK CRANE-MODEL 430-TC 30-TON P&H.HE WAS WORKING ALONE UNDER THE BOOM WHICH WAS APPROXIMATELY 3'-4' OFF THE GROUND WITH NO SUPPORTING TIMBERS UNDERNEATH IT. IT IS STRICTLY AGAINST COMPANY PROCEDURE TO BE DOING THIS WORK ALONE AND ALSO TO BE PHYSICALY WORKING UNDER THE BOOM WHETHER OR NOT IT IS SUPPORTED. THE EMPLOYEE HAD APPARENTLY EASILY REMOVED THE BOTTOM PIN NEAREST HIM BETWEEN THE MIDDLE AND END SECTIONS AND HAD STOOPED DOWN UNDER THE BOOM ATTEMPTING TO KNOCK OUT THE BOTTOM PIN ON THE OPPOSITE SIDE. THIS PIN APPEARED TO HAVE BEEN LIBERALLY SPRAYED WITH LUBRICANT.THE PENDANT LINES WERE ATTACHED TO THE END SECTION OF THE BOOM PROVIDING TENSION ALONG THE ENTIRE BOOM AND WHEN THE 2ND PIN WAS REMOVED THE BOOM,WHICH WAS HINGED AT THE TOP BY TWO PINS,DROPPED DOWN ACROSS THE BACK OF THE EMPLOYEE CRUSHING HIS CHEST. HE WAS ASPHYXIATED. AT THE TIME OF THIS ACCIDENT HE WAS WORKING AT ONE OF HIS REGULARLY ASSIGNED TASKS.

Keywords: dismantling, crane boom, truck crane, crane

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 3319209 Fatality Asphyxia Heavy equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close