Accident Report Detail
Accident Summary Nr: 14443097 - Employee killed when struck by falling crane load
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 3324746 | 07/09/1985 | 1542 | 0 | Foulger Pratt Construction, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 3324753 | 07/09/1985 | 1771 | 0 | Carson Concrete Corporation |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 3324761 | 07/09/1985 | 1796 | 0 | Otis Elevator Company |
Abstract: Employee #1, age 20, was working in the open basement level of a 23-story high rise structure. A Pecco 400 tower crane was hoisting 350 lb, 24 in. square by 29 in. high electronic pulse filter units from the first floor level to the penthouse level of the building. As the load reached the 24th level, it came up underneath a 3 1/2 ft protruding ledge and was thrown from its slings. Employee #1 was working 60 ft from the load's initial pick up point when he was struck by the falling load. The crane operator, who was picking in the blind, was relying on radio communication from the signalman to maintain safe clearance.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3324746 | Hospitalized injury | Fracture | Carpenter apprentices | ||
| 2 | 3324753 | Occupation Not Listed | ||||
| 3 | 3324761 | Occupation Not Listed |