Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14440531 - Employee killed when caught between track and body of yarder

Accident Summary Nr: 14440531 -- Report ID: 1032500 -- Event Date: 01/08/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
1772597901/14/198624110Brown Brothers Construction Company, Inc.

Abstract: Employee #1 was standing between the track and the superstructure of a T3Y 50 Thunderbird log yarder, resting his chain saw on the track while he sharpened the chain. The yarder operator had completed a turn to move logs from where they were felled to the landing. When he rotated the yarder 90 degrees to lay the logs on the landing, Employee #1 became caught between the track and the superstructure. He suffered a crushed pelvis and was killed.

Keywords: YARDING, WORK RULES, CAUGHT BETWEEN, CRUSHED, PELVIS, LOGGING, COMMUNICATION, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 17725979 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.