Accident Summary Nr: 14437875 - Employee killed when crushed between debarker and tire

Accident Summary Nr: 14437875 -- Report ID: 1032500 -- Event Date: 01/19/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11051767901/20/199324210Wilson Operations, Inc.

Abstract: A drum debarker is a large drum (cylinder) that lies horizontally and rotates. Tree logs are placed inside the drum to remove the bark. The drum is cradled between eight sets of dual tires, which rotate the drum. Employee #1 was apparently trying to clear debris from the bark conveyor belt that runs under the drum when he was caught between the rotating drum and one set of the dual tires and severely crushed. His body rotated completely through the pinch point and fell to the ground. Employee #1 apparently died instantly of massive internal and external injuries. The area between the rotating drum and the drive tires was not guarded to prevent entry and the machinery was not shut down and locked out before Employee #1 entered the hazard area.

Keywords: WORK RULES, DRUM, LOCKOUT, CAUGHT BETWEEN, CRUSHED, NIP POINT, UNGUARDED, TIRE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110517679 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close