Accident Summary Nr: 14434203 - Employee killed in fall with ladder

Accident Summary Nr: 14434203 -- Report ID: 0951510 -- Event Date: 10/10/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10386963210/25/198817610Paradise Roofing Inc

Abstract: Employee #1, a roofing foreman, was helping to remove asphalt shingles and felt underlayment prior to reroofing. He was last observed by a coworker to be on a ladder at the eaves level; the coworker then heard Employee #1 and the ladder fall. Employee #1 suffered massive head injuries and died on October 13, 1988. No casual factors were determined, but subsequent interviews revealed that the ladder was unsecured, and this may have contributed to the accident. The roof pitch was 4 in12, and the height from the eaves to the lower level was approximately 13 ft.

Keywords: HEAD, UNSECURED, WORK RULES, LADDER, CONSTRUCTION, ROOFER, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103869632 Fatality Other Roofers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.