Accident Summary Nr: 14433775 - Two employees injured by falling scaffold debris

Accident Summary Nr: 14433775 -- Report ID: 0951510 -- Event Date: 02/02/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10590659802/03/198817910Associated Steel Workers Limited
Inspection NrDate OpenedSICNAICSEstablishment Name
10590682002/03/198816230Okada Trucking Co Ltd
Inspection NrDate OpenedSICNAICSEstablishment Name
10590659802/03/198817910Associated Steel Workers Limited

Abstract: At approximately 9:30 a.m. on February 2, 1988, Employees #1 and #2 were working in the perimeter of a reservoir under construction, attempting to reinforce an existing rebar column with another rebar column. The second rebar column was being hoisted by a crane belonging to the general contractor, Okada Trucking Co., Ltd. when the crane's wire rope was severed, The column dropped, striking and demolishing the scaffold beneath it. Employees #1 and #2 were struck by the falling scaffold and planking. Employee #1 sustained bruises and abrasions on his back and to his left rib. Employee #2 sustained bruises and abrasions on his right ankle. Neither employee was hospitalized. The wire rope failed because of two-blocking. Employees #1 and #2 worked for Associated Steel Works, Ltd., a subcontractor of Okada Trucking.

Keywords: WORK RULES, EQUIPMENT FAILURE, TWO-BLOCKING, CONTUSION, WIRE ROPE, BROKEN CABLE, CONSTRUCTION, STRUCK BY, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105906598 Non Hospitalized injury Bruise/Contus/Abras Structural metal workers
2 105906820 Occupation Not Listed
3 105906598 Non Hospitalized injury Bruise/Contus/Abras Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.