Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14431746 - Employee killed when struck by falling wellhead

Accident Summary Nr: 14431746 -- Report ID: 0830100 -- Event Date: 05/29/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10056819505/31/199013890Prevost Contracting

Abstract: Employee #1 had dug down approximately 3 ft around a wellhead to remove it from a wastewater injection well. The well was to be cemented and a metal plate welded over the casing. While Employee #1 was hanging on his line cutting the inside production pipe with a torch, the wellhead fell on him. He suffered multiple injuries to his spleen, liver, and kidneys. a broken collarbone, and several fractured ribs that punctured his lungs. Employee #1 was pronounced dead at the hospital in Circle, MT.

Keywords: FRACTURE, LUNG, DISMANTLING, UNSECURED, WORK RULES, OIL WELL SERVICING, STRUCK BY, WELLHEAD, FALLING OBJECT, PUNCTURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100568195 Fatality Bruise/Contus/Abras Supervisors, extractive occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close