10159080011/05/198676410Bestway Stripping

Abstract: At approximately 3:00 p.m. on November 4, 1986, Employee #1, age 19, was found unconscious, hanging over a furniture stripping tank that contained a solution of methylene chloride, methanol, and toluene. It is not known when he had lost consciousness. Attempts to resuscitate Employee #1 were unsuccessful and he was pronounced dead at 4:00 p.m. The coroner's report stated that Employee #1 had developed an acute toxic reaction to methlyene chloride and lost consciousness, but had continued to breath the vapors while he was collapsed over the stripping tank. The toxicology examination revealed a toxic concentration of methylene chloride in the blood (5l micrograms/milliliter) and urine (18 micrograms/milliliter). This was Employee's #1's first day on the job, and he had apparently only been stripping furniture for 2 hours.

Keywords: UNCONSCIOUSNESS, PPE, METHYLENE CHLORIDE, WORK RULES, INHALATION, TOLUENE, CHEMICAL VAPOR, POISONING, TOXIC FUMES, OVEREXPOSURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101590800 Fatality Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close